Détails de produit
Lieu d'origine: Chine
Nom de marque: RION
Certification: CE, FCC , ROHS
Numéro de modèle: HCA716S / HCA726S
Le document: HCA716 HCA726-CANBUS TILT S...OR.pdf
Conditions de paiement et d'expédition
Quantité de commande min: 1
Prix: $225.00pcs/Pieces
Détails d'emballage: Carton de emballage
Délai de livraison: 5 ~ 8 jours de travail
Conditions de paiement: T/T
Capacité d'approvisionnement: 1000 pièces/mois
Fonctionnement large de la température: |
-40 ~ + 85 ℃ |
Précision: |
référez-vous aux données techniques |
Petite taille: |
54 × 46 × 20,5 mm (personnalisé) |
Interface: |
CAN2.0A/CAN2.0B |
Fonctionnement large de la température: |
-40 ~ + 85 ℃ |
Précision: |
référez-vous aux données techniques |
Petite taille: |
54 × 46 × 20,5 mm (personnalisé) |
Interface: |
CAN2.0A/CAN2.0B |
HCA716S / HCA726S is a small volume high-precision single / dualaxis inclinometer developed by RION Technology for industrial field control. It adopts CAN2.0A/B serial access interface. Built-in high-precision 24bit A / D differential converter, through the 5th order filtering algorithm, can measure the tilt and pitch angle of the sensor output relative to the horizontal plane. The product integrates the latest technology main MEMS tilting unit, the measuring range up to ± 180 °, and the full-scale accuracy is 0.01 °, which can easily achieve dual-axis and single-axis tilt measurement. The product belongs to a real industrial grade product, with reliable and stable performance, good scalability, and multiple output options. It is suitable for the application of monitoring of ancient buildings, dilapidated buildings, ancient walls, etc., and large-scale high-precision measurement in industrial sites.
| HCA716/726-C2/C3 | CONDITION | PARAMETER | UNIT | |||||
|---|---|---|---|---|---|---|---|---|
| Measure range | ±10 | ±30 | ±60 | ±90 | ±180 | ° | ||
| Measure axis | X Y | X Y | X Y | X Y | Vertical X axis | axis | ||
| Resolution | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 | ° | ||
| Measure accuracy | MAXE | Room temp. | 0.008 | 0.01 | 0.01 | 0.02 | 0.02 | ° |
| RMSE | Room temp. | 0.004 | 0.005 | 0.005 | 0.006 | 0.006 | ° | |
| Long temp. stability | <0.02 | <0.02 | <0.02 | <0.02 | <0.02 | ° | ||
| Zero Temp.coefficient | -40~85℃ | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 | ±0.0005 | °/℃ | |
| Sensitivity temp-coeffi | -40~85℃ | ≤0.01 | ≤0.01 | ≤0.01 | ≤0.01 | ≤0.01 | %/℃ | |
| Power on time | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | S | ||
| Response frequency | 20 | 20 | 20 | 20 | 20 | Hz | ||
| Interface | CAN2.0A/CAN2.0B | |||||||
| EMC | According to EN61000 and GBT17626 | |||||||
| MTBF | ≥98000 Hours/times | |||||||
| Insulation Resistance | ≥100M | |||||||
| Shockproof | 100g@11ms, 3 Axial Direction (Half Sinusoid) | |||||||
| Anti-vibration | 10grms, 10~1000Hz | |||||||
| Protection grade | IP67 | |||||||
| Cables | Standard 1M length / wear proof / grease proofing / wide temperature, Shielded cables 4*0.2mm2 | |||||||
| Weight | ≤150g (including 1 meter cable) | |||||||